  "site": "confined-space.com",
  "last_updated": "2026-10-30",
  "note": "Core = the section the course is primarily built around. Referenced = covered as supporting/overlap content. This mapping describes course design intent, not a legal certification that a specific student meets every duty under a given section.",
  "source_url": "https://confined-space.com/osha-standards-crosswalk/",
  "legend": {
    "primary": "Overview standard the course is built on",
    "core": "Section the course is primarily built around",
    "referenced": "Covered as supporting or overlap content",
    "overview_only": "Introduced at overview level only",
    "not_covered": "Not covered"
  },
  "rows": [
    {
      "section": "29 CFR 1926 Subpart AA",
      "title": "Confined Spaces in Construction (overview)",
      "covers": "Identifying/classifying spaces, written permit program, training, rescue planning.",
      "official_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926subpartaa",
      "coverage": {
        "awareness": "primary",
        "entry": "primary",
        "supervisor": "primary",
        "competent": "primary"
      }
    },
    {
      "section": "29 CFR 1926.1207",
      "title": "Training",
      "covers": "Who must be trained, in what, and when retraining is required.",
      "official_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.1207",
      "coverage": {
        "awareness": "core",
        "entry": "core",
        "supervisor": "referenced",
        "competent": "referenced"
      }
    },
    {
      "section": "29 CFR 1926.1208",
      "title": "Duties of Authorized Entrants",
      "covers": "What an entrant must know and do before, during, and after entry.",
      "official_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.1208",
      "coverage": {
        "awareness": "overview_only",
        "entry": "core",
        "supervisor": "referenced",
        "competent": "referenced"
      }
    },
    {
      "section": "29 CFR 1926.1209",
      "title": "Duties of Attendants",
      "covers": "Continuous monitoring, communication, and evacuation authority.",
      "official_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.1209",
      "coverage": {
        "awareness": "overview_only",
        "entry": "core",
        "supervisor": "referenced",
        "competent": "referenced"
      }
    },
    {
      "section": "29 CFR 1926.1210",
      "title": "Duties of Entry Supervisors",
      "covers": "Authorization, verification, and oversight of permit-required entries.",
      "official_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.1210",
      "coverage": {
        "awareness": "not_covered",
        "entry": "referenced",
        "supervisor": "core",
        "competent": "referenced"
      }
    },
    {
      "section": "29 CFR 1926.1211",
      "title": "Rescue and Emergency Services",
      "covers": "Verified rescue capability before entry begins.",
      "official_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.1211",
      "coverage": {
        "awareness": "not_covered",
        "entry": "referenced",
        "supervisor": "core",
        "competent": "core"
      }
    },
    {
      "section": "29 CFR 1910.146",
      "title": "General Industry Permit-Required Confined Spaces",
      "covers": "General industry counterpart to Subpart AA, sharing the same core roles.",
      "official_url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.146",
      "coverage": {
        "awareness": "referenced",
        "entry": "referenced",
        "supervisor": "referenced",
        "competent": "referenced"
      }
    }
  ]
}