Free Interactive Tool

Confined Space Gas Reading Checker: Are Your 4-Gas Readings Acceptable?

Enter your monitor's oxygen, flammable gas, hydrogen sulfide and carbon monoxide readings to see how they compare with OSHA's limits and common alarm setpoints.

  • Runs in your browser
  • Nothing is saved
On this page
  1. Calculator
  2. The limits used
  3. Reading the results
  4. FAQ

A 4-gas monitor reports oxygen, flammable gas as a percentage of the lower explosive limit (LEL), hydrogen sulfide and carbon monoxide. This checker compares your readings with OSHA's definition of a hazardous atmosphere and the alarm setpoints most monitors use out of the box.

The limits used

GasAcceptable range used hereReference
Oxygen19.5% to 23.5%OSHA: below 19.5% is deficient, above 23.5% is enriched
Flammable gasBelow 10% LELOSHA: above 10% of the LFL is a hazardous atmosphere
Hydrogen sulfideBelow 10 ppmCommon alarm; OSHA general industry ceiling 20 ppm; construction PEL 10 ppm; NIOSH ceiling 10 ppm; IDLH 100 ppm
Carbon monoxideBelow 35 ppmCommon alarm; OSHA PEL 50 ppm; NIOSH REL 35 ppm; IDLH 1,200 ppm

Reading the results

  • One reading out of range means don't enter. Ventilate, isolate or clean, then retest.
  • Normal air is about 20.9% oxygen. A reading of 20.0% is still "acceptable" but means something is displacing or consuming oxygen. Find out why.
  • Test at all levels before entry. A good reading at the opening says nothing about the bottom of the space. See atmospheric testing.
  • Your permit's acceptable entry conditions control. Some programs set tighter limits, and other contaminants need their own.

Sources and official references

Last reviewed: October 25, 2026 · Free general education based on OSHA 29 CFR 1910.146 and 29 CFR 1926 Subpart AA. It does not replace the site-specific training, written program and hands-on evaluation your employer must provide, and it does not issue a certificate. Nothing you enter on this page is saved or sent.

FAQ

Frequently asked questions

OSHA treats oxygen below 19.5% as deficient and above 23.5% as enriched, so acceptable oxygen is 19.5% to 23.5%. Normal air is about 20.9%.

Under 29 CFR 1910.146, a flammable gas above 10% of its lower flammable limit is a hazardous atmosphere, so readings must be below 10% LEL. Many programs alarm at 10% LEL.

Common factory settings are oxygen low 19.5% and high 23.5%, flammable gas 10% LEL, hydrogen sulfide 10 ppm and carbon monoxide 35 ppm. Check your monitor and your entry permit.