Confined Space Ventilation Calculator: How Long to Purge Before Entry

Estimate how long a blower must run to purge a tank, vault or manhole before entry, and how many air changes per hour it delivers during the job.

  • Runs in your browser
  • Nothing is saved
On this page
  1. Calculator
  2. The formula
  3. Setup matters more than the math
  4. FAQ

Purging dilutes and removes contaminants before entry. The usual way to estimate it is by air changes: how many times the volume of the space is replaced with fresh air.

The formula

Purge time (minutes) = volume (cubic feet) × air changes ÷ effective airflow (CFM)

  • Volume: cylinder = 3.14 × radius² × height; rectangle = length × width × height.
  • Effective airflow: the blower's rating minus losses from duct length, bends and elevation. Manufacturers publish charts; long runs with several bends can cut airflow by a third or more.
  • Air changes: set by your program or the manufacturer. Many programs use 7 or more air changes to purge.

Setup matters more than the math

  • Intake upwind, away from engine exhaust.
  • Supply duct reaching the work area or bottom so air sweeps the whole space.
  • Never ventilate with oxygen.
  • Keep ventilating during entry, and evacuate if the blower stops.

Learn the full method in the free ventilation lesson.

Sources and official references

Last reviewed: October 25, 2026 · Free general education based on OSHA 29 CFR 1910.146 and 29 CFR 1926 Subpart AA. It does not replace the site-specific training, written program and hands-on evaluation your employer must provide, and it does not issue a certificate. Nothing you enter on this page is saved or sent.

FAQ

Frequently asked questions

Multiply the space volume in cubic feet by the number of air changes, then divide by the blower's effective airflow in cubic feet per minute. Always test the atmosphere afterward, because purge time is only an estimate.

It depends on the contaminant and your program or the blower manufacturer's guidance. Many programs use at least 7 air changes before testing, and more for heavy contamination.

Not by itself. Ventilation controls atmospheric hazards, but entry requires testing at all levels, continued monitoring and the other controls on the permit.