Regulatory Reference
OSHA Confined Space Standards Explained
Plain-language summaries of the standards our courses are aligned with, each linked to the official OSHA source. This page is general guidance, not legal advice.
Construction
29 CFR 1926 Subpart AA
Subpart AA Overview →
Confined Spaces in Construction. Requires identifying and classifying confined spaces on a construction site, a written permit program, training for every role, and rescue/emergency planning specific to construction work.
1926.1207: Training
Sets who must be trained, in what, and how retraining works when duties, hazards, or performance issues change. This is the section our Awareness and Entry courses are built around.
1926.1208: Duties of Authorized Entrants
What an entrant must know and do before, during, and after entering a permit space, covered in Permit-Required Entry training.
1926.1209: Duties of Attendants
The attendant's continuous monitoring, communication, and evacuation-authority duties, also covered in Permit-Required Entry training.
1926.1210: Duties of Entry Supervisors
Authorization, verification, and oversight duties for the entry supervisor, covered in Supervisor training.
1926.1211: Rescue & Emergency Services
Requirements for verified rescue capability before entry begins, covered in Supervisor and Competent Person training, and in our rescue planning guide.
General Industry
29 CFR 1910.146
1910.146 Overview →
Permit-Required Confined Spaces for General Industry. The general industry counterpart to 1926 Subpart AA, sharing the same core roles and permit concepts.
How It Differs From Subpart AA
1910.146 predates Subpart AA and doesn't include construction-specific requirements like continuous atmospheric monitoring or multi-employer information exchange that construction sites need.
OSHA Training FAQ
OSHA's general guidance on training delivery methods, including where online/computer-based training fits. Read it →
State Rules
State Plans May Differ
Roughly half the states run their own OSHA-approved State Plan, which must be at least as protective as federal OSHA and sometimes adds requirements. See our State OSHA Plan Requirements guide or OSHA's official State Plans directory →.
This page is provided for general guidance and training purposes and is not legal advice. Regulatory text, enforcement practices, and links can change. Confirm current requirements for your specific site and project with qualified counsel or OSHA directly before relying on them.
Key definitions
The definitions that drive everything
Both standards start from the same core definitions:
- Confined space: large enough to bodily enter and perform work, has limited or restricted means for entry or exit, and is not designed for continuous employee occupancy.
- Permit-required confined space: a confined space that contains or may contain a hazardous atmosphere, contains a material that could engulf an entrant, has an internal configuration that could trap or asphyxiate an entrant, or contains any other recognized serious safety or health hazard.
- Entry: the action by which any part of a person's body breaks the plane of an opening into the space.
When the atmosphere is "hazardous"
OSHA defines a hazardous atmosphere as one that may expose employees to death, incapacitation, injury or acute illness from:
| Condition | Threshold |
|---|---|
| Flammable gas, vapor or mist | In excess of 10% of its lower flammable limit (LFL) |
| Airborne combustible dust | At or above its LFL (approximated as dust that obscures vision at 5 feet or less) |
| Oxygen | Below 19.5% or above 23.5% |
| Toxic substances | Above the dose or permissible exposure limit in OSHA's health standards |
| Other | Any atmospheric condition immediately dangerous to life or health |
Try these limits with the free gas reading checker, or learn them in the atmospheric testing lesson.
Alternate procedures and reclassification
Not every permit space requires the full permit system every time. Both standards allow:
- Alternate procedures when the only hazard is an actual or potential hazardous atmosphere that can be controlled by continuous forced-air ventilation alone, with monitoring and documentation showing it stays safe.
- Reclassification of a permit space as a non-permit space when there are no actual or potential atmospheric hazards and all other hazards are eliminated without entry, or are eliminated by entry under permit, with the basis documented and certified.
Both options come with specific conditions and paperwork, which our Competent Person and Supervisor courses cover. Our free permit-space decision tool walks through the classification questions.
Find the Course That Matches Your Role
Four courses, online. Certificate on completion. English & Spanish.